Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13691528
![](http://i.b2b168.com/e/tag_pthy.gif)
- Product Categories
- Friendly Links
Information Name: | 4-way intelligent lighting switch control module |
Published: | 2015-05-30 |
Validity: | 0 |
Specifications: | ∷≮ intelligent lighting system ≯, mainly for two purposes: to reduce the maintenance costs of the lighting system; reduce maintenance costs of the lighting system |
Quantity: | 1000.00 |
Price Description: | |
Detailed Product Description: | The company provides <> 'every customer to buy a desirable product: "the spot inventory, with prices lowest in the world's most affordable" 4-way switch control module intelligent lighting "Spot warehousing ◎ intelligent lighting control systems F ◎ MISS "Contact: Yang Guang, hotline: 13695854666, Contact: Yang Guang landline: 0577-61770678 Fax: 0577-61770679 Mobile: 13695854666 Note: Provide a variety of solutions, technical support, product by factory warranty 2 In Shengtai Electric help you - make its efficacy, most of your energy, there Sheng Tai, the use of products with more confidence, product promotion. . . Intelligent switch module uses a manual outlining intelligent switch module, communication bus 485, comes with scene control section, itself has a relay switch manual control, with remote programming and management functions. Second, the functional characteristics 1.12 relay switch output unit 2. The scene controller comes with up to 128 scenes 3. Each circuit has a lighting protection delay (0-60 minutes) 4. Each circuit has a partial opening Delay (0-25 seconds) 5. Each circuit relay switch can be manually controlled with remote programming and management 6. 7. The device features selectable restart has been opened scene or specified scene 8. communicate using 485 9. STANDARD 35mm rail mounting structure Third, the main technical parameters 1. Input voltage: DC24V 2. bus power consumption: 35mA / DC24V 3. switch circuit: 12 Road 4. Each switch circuit maximum current: 16A 5. Relay Electrical life: more than 60,000 times (resistive load) 6. Environmental conditions: Operating temperature 0 ℃ ~ 45 ℃ Relative humidity 20% ~ 90% Storage Temperature -40 ℃ ~ + 55 ℃ Storage relative humidity of 10% to 93% 7. Dimensions: 165mm × 88mm × 66mm 8. Weight: 0.6kg Fourth, installation and connection 1. Installation conditions to be ventilated installation location, pay attention to moisture, shock and dust. 2. Wiring specifications l The module relay switch output cable: 2.5mm2 copper wire l 485 bus cable: use UTP twisted pair wire or 4-wire 3. Typical systems are typically connected to the module connection system (reference) as shown below. Connection for device switch control, lighting control (including scene control, etc.) through 485 with the control panel, system management servers, systems management, and connection with other control systems and so on. Fifth, the function and operation instructions 1, relay switch manual control of the module in addition to receiving an external signal switching control, it can also be manually controlled switch. 1 to 4, by operating the manual switch relay circuit, which can control from 1 to 4 loops on and off. 2, the machine ID number on the device must be "SILO system control software," settings, set to see the software. 3, Scene up to 128 scenes, each scene is a combination of any of the loop together. Scene must be "SILO system control software" to set up, see the software settings. 4, open-loop and open-loop protection delay delay: Each loop can be set on delay is, after the loop start, reaches only delay the value of the output circuit. On delay effects, while simultaneously start multiple loop circuit according to the latency value to start up, to avoid the impact of high current all started. Note: on delay values ??ranging from 0.0 to 25.0 seconds. Circuit protection delay: Each loop can be set to protect the delay, that is, when a circuit output is shut off, in order to protect the load, only time delay to protect the value of the loop output can no longer be controlled. Note: The protection delay values ??ranging from 00 to 60 points. On delay, the relay delay value must be set by "SILO system control software", set reflected in its instructions. 5, reboot run farm settings (power recovery scenarios set) system set to open the field, after the machine reboots, run the last scene when turned off. After the system is set for the specified field, restart the machine will run the specified scene. Sets by "SILO system control software", set reflected explained. The default does not run the scene after the restart. Sixth, safe use and maintenance of not less than 1.485 buses 16V, otherwise the relay is not working properly. 2. Each loop must be connected to AC220V ~ 240V power supply via a suitable circuit breaker. To be safe with the relay, should note the following: l For connecting a resistive load, the load current of each loop can be up to 16A. l For the connection of inductive loads (high voltage), connect capacitive loads (with inrush current), the maximum load current per circuit should be less than 16A. Specific suitable load power factor of the actual load size, selected in accordance with, the power factor is smaller, the smaller the selected load. l especially for connecting low power factor loads, such as low power factor energy-saving lamps, low power factor electronic ballast lamps, etc., because of the impact of current, in order to protect the safety relay used should be appropriate to reduce the load, in order to reduce the inrush current. 4. Do not close jamming equipment. 5. To establish a good ventilation environment. 6. During use, pay attention to moisture, shock and dust. 7. When the machine fails, please contact qualified service personnel or the Company. |
Admin>>>
You are the 10258 visitor
Copyright © GuangDong ICP No. 10089450, Wenzhou Sheng Tai Electric Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 10258 visitor
Copyright © GuangDong ICP No. 10089450, Wenzhou Sheng Tai Electric Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility