Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13691528
![](http://i.b2b168.com/e/tag_pthy.gif)
- Product Categories
- Friendly Links
Information Name: | 8-way intelligent switch drive |
Published: | 2015-04-07 |
Validity: | 0 |
Specifications: | |
Quantity: | 1000.00 |
Price Description: | |
Detailed Product Description: | Sheng Tai (supply) sales of smart switch driver 8-way products for automated lighting control, remote lighting management systems, identification management make lighting more energy efficient, easier to control, to maximize efficiency! Years of experience, the vast number of consumers recognized ............ Contact: Yang Guang landline: 0577-61770678 Fax: 0577-61770679 Mobile: 13695854666 I. Overview ST12.16.1 intelligent switch module, communication bus 485, comes with a scene control section, which have their own relay switch manual control, with remote programming and management capabilities. Second, the functional characteristics 1.12 relay switch output unit 2. The scene controller comes with up to 128 scenes 3. Each loop has a lighting protection delay (0-60 minutes) 4. Each loop has a partial open delay (0-25 seconds) 5. Each loop 6. relay switch can be manually controlled with remote programming and management capabilities 7. Reboot optional equipment has been opened scene or specified scene 8. 9. communicate using a standard 485 35mm rail mounting structure Main technical parameters 1. Input voltage: DC24V 2. bus power consumption: 35mA / DC24V 3. switch circuit: 12 Road 4. Each switch circuit maximum current: 16A 5. Relay Electrical life: more than 60,000 times (resistive load) 6. Environmental conditions: Operating temperature 0 ℃ ~ 45 ℃ Relative humidity 20% ~ 90% Storage temperature -40 ℃ ~ + 55 ℃ Storage relative humidity of 10% to 93% 7. Dimensions: 165mm × 88mm × 66mm 8. Weight: 0.6kg Fourth, the appearance and the appearance of explanation module wiring diagram is as follows: ① 1,2,3,4,5,6,7,8,9,10,11,12 12 relay switch the output circuit ② loop indicator. 12 lights and 12 respectively correspond to the manual switch button, each indicator shows the status of the corresponding switch circuit. ③ 1,2,3,4,5,6,7,8,9,10,11,12 12 relay manual button after each press, relay status with the current state of the opposite. ④ When the power supply and unusual light, when the module is working properly, the light flashes once per second (slow flash), abnormal conditions, the indicator flashes once (flash) every 250ms. ⑤ DC +, DATA +, DATA-, COM 485 bus terminal terminal signal definitions and correspondence between the 485-wired for: DC + (+ 24V) → brown, orange DATA + (signal +) → blue, green DATA- (signal - ) → blue, green and white COM (Common) → brown white, orange and white ⑥ Fire signal interface. DI-, DI + for the fire signal input interface, DO-, DO + feedback output interface for the fire. Both interfaces are active signal, need external access to power, DI-, DI + only allows the DC voltage input range is DC5V-30V; DO-, DO + also allows only a DC voltage input range is DC5V-30V, with driving DC12V, DC24V relays and other equipment, both of which do not access to 220V AC signal, in order to avoid damage to the equipment. When the system default input signal fire, triggering all circuits open, feedback output interface connected; when the fire signal is restored, restore the original state of the circuit, the feedback output interface is disconnected; above signals can be programmed to trigger a scene changes. Fifth, installation and connection 1. Installation conditions to be ventilated installation location, pay attention to moisture, shock and dust. 2. Wiring specifications l This module relay switch the output cable: 2.5mm2 copper wire l 485 bus cable: the super five-wire or 4-wire twisted pair 3. Typical systems are typically connected to the system is connected to the module (for reference) as shown below. Enables devices to connect switch control, lighting control (including scene control, etc.) via the control panel 485, system management servers, systems management, and connection with other control systems and so on. Six, functions and operating instructions a relay switch manual control of the module in addition to receiving an external signal switching control, can also be manually controlled switch. By operating a relay circuit to 12 manual switch, which can control 1 to 12 circuits on and off. 2, the machine ID number on the device must be "SILO System Control Software" settings, set to see the software instructions. 3, Scene up to 128 scenes, each scene is a combination of any of the loop together. Scene must pass "SILO system control software" to set, see the software settings. 4, open-loop and open-loop protection delay delay: Each loop can be set to turn on delay, loop-start after that, reaching the loop only when the value of the output of the delay. Effect on delay, while simultaneously launch multiple loops, loop start followed by the delay value to avoid the impact of high current all started. Note: on delay values ??ranging from 0.0 to 25.0 seconds. Circuit protection delay: Each loop can be set up to protect the delay, that is, when a circuit output turns off, in order to protect the load, only time delay to protect the value of the loop output can no longer be controlled. Note: protection delay values ??ranging from 00 to 60 points. On delay value, protect the delay value must be set by "SILO system control software", set reflected instructions. 5. The field is set to run after reboot (power-recovery scenarios set) as the system set to open the field, after restarting the machine will run the last scene when turned off. After the system is set for the specified field, the machine reboots, will run the specified scene. Sets by "SILO system control software", set reflected instructions. The default scenario is not running after the restart. Safe use and maintenance of the bus can not be less than 1.485 16V, otherwise the relay does not work. 2. Each loop must access AC220V ~ 240V power supply through the appropriate circuit breaker. 3. In order to secure the use of relays, should note the following: l For connecting a resistive load, the load current of each loop can be up to 16A. l For the connection of inductive loads (high voltage), connect the capacitive load (with the impact of current), each circuit should be less than the maximum load current of 16A. Specific suitable load actual size of the load power factor, selected according to the lower the power factor, the smaller the selected load. l especially for low power factor load is connected, such as low power factor energy-saving lamps, low power factor electronic ballast lamps, etc., due to the impact of current, in order to protect the safety relay used should be appropriate to reduce the load, in order to reduce the impact of current. 4. Do not close to the jamming equipment. 5. To establish a good ventilation environment. 6. During use, pay attention to moisture, shock and dust. 7. When the machine fails, contact qualified service personnel or the Company. ST8.16.1 intelligent switch module uses a manual outlining ST8.16.1 intelligent switch module, the communication bus 485, comes with scene control section, which have their own relay switch manual control, with remote programming and management capabilities. Second, features 1.8-channel relay output unit 2. The switch comes with a scene controller, up to 128 scenes 3. Each loop has a lighting protection delay (0-60 minutes) 4. Each loop has a partial open delay (0-25 seconds) 5. Each loop 6. relay switch can be manually controlled with remote programming and management capabilities 7. Reboot optional equipment has been opened scene or specified scene 8. 9. communicate using a standard 485 35mm rail mounting structure Main technical parameters 1. Input voltage: DC24V 2. bus power consumption: 30mA / DC24V 3. switch circuit: 8 4. Each switch circuit maximum current: 16A 5. Relay Electrical life: more than 60,000 times (resistive load) 6. Environmental conditions: Operating temperature 0 ℃ ~ 45 ℃ Relative humidity 20% ~ 90% Storage temperature -40 ℃ ~ + 55 ℃ Storage relative humidity of 10% to 93% 7. Dimensions: 165mm × 88mm × 66mm 8. Weight: 0.5kg Fourth, the appearance and the appearance of explanation module wiring diagram is as follows: ① 1,2,3,4,5,6,7,8 total of eight relay switches the output circuit ② circuit indicator. 8 LEDs and 8 respectively correspond to the manual switch button, each indicator shows the status of the corresponding switch circuit. ③ 1,2,3,4,5,6,7,8 total of eight relay manual button after each press, relay status with the current state of the opposite. ④ When the power supply and unusual light, when the module is working properly, the light flashes once per second (slow flash), abnormal conditions, the indicator flashes once (flash) every 250ms. ⑤ DC +, DATA +, DATA-, COM 485 bus terminal terminal signal definitions and correspondence between the 485-wired for: DC + (+ 24V) → brown, orange DATA + (signal +) → blue, green DATA- (signal - ) → blue, green and white COM (Common) → brown white, orange and white ⑥ Fire signal interface. DI-, DI + for the fire signal input interface, DO-, DO + feedback output interface for the fire. Both interfaces are active signal, need external access to power, DI-, DI + only allows the DC voltage input range is DC5V-30V; DO-, DO + also allows only a DC voltage input range is DC5V-30V, with driving DC12V, DC24V relays and other equipment, both of which do not access to 220V AC signal, in order to avoid damage to the equipment. When the system default input signal fire, triggering all circuits open, feedback output interface connected; when the fire signal is restored, restore the original state of the circuit, the feedback output interface is disconnected; above signals can be programmed to trigger a scene changes. Fifth, installation and connection 1. Installation conditions to be ventilated installation location, pay attention to moisture, shock and dust. 2. Wiring specifications l This module relay switch the output cable: 2.5mm2 copper wire l 485 bus cable: the super five-wire or 4-wire twisted pair 3. Typical systems are typically connected to the system is connected to the module (for reference) as shown below. Enables devices to connect switch control, lighting control (including scene control, etc.) via the control panel 485, system management servers, systems management, and connection with other control systems and so on. Six, functions and operating instructions a relay switch manual control of the module in addition to receiving an external signal switching control, can also be manually controlled switch. 1-8 loop through the operation of the relay manual switch, which can control a 1-8 loop and off. 2, the machine ID number on the device must be "SILO System Control Software" settings, set to see the software instructions. 3, Scene up to 128 scenes, each scene is a combination of any of the loop together. Scene must pass "SILO system control software" to set, see the software settings. 4, open-loop and open-loop protection delay delay: Each loop can be set to turn on delay, loop-start after that, reaching the loop only when the value of the output of the delay. Effect on delay, while simultaneously launch multiple loops, loop start followed by the delay value to avoid the impact of high current all started. Note: on delay values ??ranging from 0.0 to 25.0 seconds. Circuit protection delay: Each loop can be set up to protect the delay, that is, when a circuit output turns off, in order to protect the load, only time delay to protect the value of the loop output can no longer be controlled. Note: protection delay values ??ranging from 00 to 60 points. On delay value, protect the delay value must be set by "SILO system control software", set reflected instructions. 5. The field is set to run after reboot (power-recovery scenarios set) as the system set to open the field, after restarting the machine will run the last scene when turned off. After the system is set for the specified field, the machine reboots, will run the specified scene. Sets by "SILO system control software", set reflected instructions. The default scenario is not running after the restart. Safe use and maintenance of the bus can not be less than 1.485 16V, otherwise the relay does not work. 2. Each loop must access AC220V ~ 240V power supply through the appropriate circuit breaker. 3. In order to secure the use of relays, should note the following: l For connecting a resistive load, the load current of each loop can be up to 16A. l For the connection of inductive loads (high voltage), connect the capacitive load (with the impact of current), each circuit should be less than the maximum load current of 16A. Specific suitable load actual size of the load power factor, selected according to the lower the power factor, the smaller the selected load. l especially for low power factor load is connected, such as low power factor energy-saving lamps, low power factor electronic ballast lamps, etc., due to the impact of current, in order to protect the safety relay used should be appropriate to reduce the load, in order to reduce the impact of current. 4. Do not close to the jamming equipment. 5. To establish a good ventilation environment. 6. During use, pay attention to moisture, shock and dust. 7. When the machine fails, contact qualified service personnel or the Company. ST6.16.1 intelligent switch module uses a manual outlining ST6.16.1 intelligent switch module, the communication bus 485, comes with scene control section, which have their own relay switch manual control, with remote programming and management capabilities. Second, features 1.6-channel relay output unit 2. The switch comes with a scene controller, up to 128 scenes 3. Each loop has a lighting protection delay (0-60 minutes) 4. Each loop has a partial open delay (0-25 seconds) 5. Each loop 6. relay switch can be manually controlled with remote programming and management capabilities 7. Reboot optional equipment has been opened scene or specified scene 8. 9. communicate using a standard 485 35mm rail mounting structure Main technical parameters 1. Input voltage: DC24V 2. bus power consumption: 20mA / DC24V 3. switch circuit: 6 Road 4. Each switch circuit maximum current: 16A 5. Relay Electrical life: more than 60,000 times (resistive load) 6. Environmental conditions: Operating temperature 0 ℃ ~ 45 ℃ Relative humidity 20% ~ 90% Storage temperature -40 ℃ ~ + 55 ℃ Storage relative humidity of 10% to 93% 7. Dimensions: 108mm × 88mm × 66mm 8. Weight: 0.4kg Fourth, the appearance and the appearance of explanation module wiring diagram is as follows: ① 1,2,3,4,5,6 6 relay switch circuit output terminal ② circuit indicator. 6 LEDs and 6 respectively correspond to the manual switch button, each indicator shows the status of the corresponding switch circuit. ③ 1,2,3,4,5,6 6 relay manual button after each press, relay status with the current state of the opposite. ④ When the power supply and unusual light, when the module is working properly, the light flashes once per second (slow flash), abnormal conditions, the indicator flashes once (flash) every 250ms. ⑤ DC +, DATA +, DATA-, COM 485 bus terminal terminal signal definitions and correspondence between the 485-wired for: DC + (+ 24V) → brown, orange DATA + (signal +) → blue, green DATA- (signal - ) → blue, green and white COM (Common) → brown white, orange and white ⑥ Fire signal interface. DI-, DI + for the fire signal input interface, DO-, DO + feedback output interface for the fire. Both interfaces are active signal, need external access to power, DI-, DI + only allows the DC voltage input range is DC5V-30V; DO-, DO + also allows only a DC voltage input range is DC5V-30V, with driving DC12V, DC24V relays and other equipment, both of which do not access to 220V AC signal, in order to avoid damage to the equipment. When the system default input signal fire, triggering all circuits open, feedback output interface connected; when the fire signal is restored, restore the original state of the circuit, the feedback output interface is disconnected; above signals can be programmed to trigger a scene changes. Fifth, installation and connection 1. Installation conditions to be ventilated installation location, pay attention to moisture, shock and dust. 2. Wiring specifications l This module relay switch the output cable: 2.5mm2 copper wire l 485 bus cable: the super five-wire or 4-wire twisted pair 3. Typical systems are typically connected to the system is connected to the module (for reference) as shown below. Enables devices to connect switch control, lighting control (including scene control, etc.) via the control panel 485, system management servers, systems management, and connection with other control systems and so on. Six, functions and operating instructions a relay switch manual control of the module in addition to receiving an external signal switching control, can also be manually controlled switch. 1-6 by operating the manual switch relay circuit, which can control circuits 1-6 and off. 2, the machine ID number on the device must be "SILO System Control Software" settings, set to see the software instructions. 3, Scene up to 128 scenes, each scene is a combination of any of the loop together. Scene must pass "SILO system control software" to set, see the software settings. 4, open-loop and open-loop protection delay delay: Each loop can be set to turn on delay, loop-start after that, reaching the loop only when the value of the output of the delay. Effect on delay, while simultaneously launch multiple loops, loop start followed by the delay value to avoid the impact of high current all started. Note: on delay values ??ranging from 0.0 to 25.0 seconds. Circuit protection delay: Each loop can be set up to protect the delay, that is, when a circuit output turns off, in order to protect the load, only time delay to protect the value of the loop output can no longer be controlled. Note: protection delay values ??ranging from 00 to 60 points. On delay value, protect the delay value must be set by "SILO system control software", set reflected instructions. 5. The field is set to run after reboot (power-recovery scenarios set) as the system set to open the field, after restarting the machine will run the last scene when turned off. After the system is set for the specified field, the machine reboots, will run the specified scene. Sets by "SILO system control software", set reflected instructions. The default scenario is not running after the restart. Safe use and maintenance of the bus can not be less than 1.485 16V, otherwise the relay does not work. 2. Each loop must access AC220V ~ 240V power supply through the appropriate circuit breaker. 3. In order to secure the use of relays, should note the following: l For connecting a resistive load, the load current of each loop can be up to 16A. l For the connection of inductive loads (high voltage), connect the capacitive load (with the impact of current), each circuit should be less than the maximum load current of 16A. Specific suitable load actual size of the load power factor, selected according to the lower the power factor, the smaller the selected load. l especially for low power factor load is connected, such as low power factor energy-saving lamps, low power factor electronic ballast lamps, etc., due to the impact of current, in order to protect the safety relay used should be appropriate to reduce the load, in order to reduce the impact of current. 4. Do not close to the jamming equipment. 5. To establish a good ventilation environment. 6. During use, pay attention to moisture, shock and dust. 7. When the machine fails, contact qualified service personnel or the Company. TLC3.1.1 logic timing module manual I. Overview logic timing module, built-in scenes and timing, so that the module on the bus according to a pre-set a good date and time, automatically run a scenario, no background control software, you can achieve automatic control function . Built-in high-precision timing function of latitude and longitude, the location of the device can automatically according to latitude and longitude, to calculate the daily sunrise and sunset times, and trigger the appropriate scene, this function is especially suitable for building, outdoor lighting and street automatic control and other applications. Second, Features 1. E-BUS interface with built-in 128 scenes 2. 3. 4. Built-in high-precision timer 128 5. 6. Latitude timing network time management capabilities with remote programming and proofreading 7. 10M / 100M Ethernet 8. interface standard 35mm rail mounting structure Main technical parameters 1. Input voltage: DC24V 2. Bus consumption: 100mA / DC24V 3. Signal Interface: IP signal interface, E-BUS signal interface 4. Environmental conditions: Operating temperature 0 ℃ ~ 45 ℃ Relative humidity 20% ~ 90% Storage temperature -40 ℃ ~ + 55 ℃ Storage relative humidity of 10% to 93% 5. Dimensions: 110mm × 88mm × 66mm 6. Weight: 0.25kg four, Appearance Description When ① Power and unusual light, when the module to work, blinks once per second (slow flash), abnormal situation, the indicator flashes once (flash) every 250ms. ② RJ45 network interface, via UTP cable or connect the computer directly connected to the router. ③ DC +, DATA +, DATA-, COM 485 bus terminal terminal signal definitions and correspondence between the 485-wired for: DC + (+ 24V) → brown, orange DATA + (signal +) → blue, green DATA- (signal - ) → blue, green and white COM (Common) → brown white, orange and white five, installation and connection 1. Installation conditions to be ventilated installation location, pay attention to moisture, shock and dust. 2. L RJ45 cable wiring specifications: The five lines l 485 bus cable: 3 ultra-five lines. Typical systems are typically connected to the system is connected to the module (for reference) as shown below. Connected to the control panel, system management servers and other equipment can be achieved switch control, lighting control (including scene control, etc.), system management, and connection with other control systems and so on. Six, functions and operating instructions module default IP :, Mask: Gateway: Scene setting and timing settings, network timing and other feature set, the module needs through its network interface to connect to a computer or a wireless terminal, through the control software can be set. Safe use and maintenance of detailed 1. Read all instructions before use. 2. Do not close to the jamming equipment. 3. To establish a good ventilation environment. 4. During use, pay attention to moisture, shock and dust. 5. When the machine fails, contact qualified service personnel or the Company. TPW24.5.1 manual TPW24.5.1 system power module that uses standard 35mm rail mounting. 220V AC input, 24VDC output. The power supply module supports dual power supply with redundancy. And each power supply module has a relay output can be used to detect the quality of the power supply module. First, the technical parameters of the working voltage 220VAC ± 10% output voltage of 24VDC, 50W Operating temperature 0 ℃ -45 ℃ Relative humidity 20% -90%, the relay output 1A, used to detect the quality of two power modules, installation instructions 1,35MM rail mounting . 2, relay output: 24V DC voltage output when there, the relay output is closed, no 24VDC output, relay output disconnect. The relay outputs can be used to detect the quality of the power supply module. Third, the function LED red running lights, module 24VDC output, running a red light is lit, the relay output is closed; if no 24VDC output, run the light is off, the relay output is disconnected; such as when an external power supply shorted running lights will flash alarm. Fourth, the wiring instructions DC +: 5.08 plug DC24V output terminals are COM: 5.08 DC24V negative output terminal block connector plug terminals L 7.62 N 7.62 220VAC plug pin FireWire input zero line input G 7.62 fixed ground terminal input DO + 7.62 fixed terminal relay the output DO- 7.62 fixed terminal relay outputs V. wiring procedure Step: 220VAC AC input connection, G earthed. Step Two: DC + and COM connect other module power input. The third step: DO +, DO- take generic module DI input is used to detect the quality of the power supply module. The figure below shows the module wiring diagram: Dual power supply connection methods DC + DC + COM COM ...................... VI Notes 1, the maximum load of the power module is 50W, which brought attention to the total load module can not be greater than 50W. 2, the power lines with a fixed color, prevent wrong, need to be carefully examined. 3, the power supply module supports dual power supply, when a module is damaged, you can ensure continued supply by another module. 4 relay outputs can be used to detect the quality of the power supply module, the access monitoring system. ST4.16.1 intelligent switch module uses a manual outlining ST4.16.1 intelligent switch module, the communication bus 485, comes with scene control section, which have their own relay switch manual control, with remote programming and management capabilities. Second, features 1.4-channel relay output unit 2. The switch comes with a scene controller, up to 128 scenes 3. Each loop has a lighting protection delay (0-60 minutes) 4. Each loop has a partial open delay (0-25 seconds) 5. Each loop 6. relay switch can be manually controlled with remote programming and management capabilities 7. Reboot optional equipment has been opened scene or specified scene 8. 9. communicate using a standard 485 35mm rail mounting structure Main technical parameters 1. Input voltage: DC24V 2. bus power consumption: 15mA / DC24V 3. switch circuit: 4 4. Each switch circuit maximum current: 16A 5. Relay Electrical life: more than 60,000 times (resistive load) 6. Environmental conditions: Operating temperature 0 ℃ ~ 45 ℃ Relative humidity 20% ~ 90% Storage temperature -40 ℃ ~ + 55 ℃ Storage relative humidity of 10% to 93% 7. Dimensions: 108mm × 88mm × 66mm 8. Weight: 0.3kg Fourth, the appearance and the appearance of explanation module wiring diagram is as follows: ① 1,2,3,4 four relay switch circuit output terminal ② circuit indicator. 4 LEDs, respectively, and 4 correspond to the manual switch button, each indicator shows the status of the corresponding switch circuit. ③ 1,2,3,4 four relay manual button after each press, relay status with the current state of the opposite. ④ When the power supply and unusual light, when the module is working properly, the light flashes once per second (slow flash), abnormal conditions, the indicator flashes once (flash) every 250ms. ⑤ DC +, DATA +, DATA-, COM 485 bus terminal terminal signal definitions and correspondence between the 485-wired for: DC + (+ 24V) → brown, orange DATA + (signal +) → blue, green DATA- (signal - ) → blue, green and white COM (Common) → brown white, orange and white ⑥ Fire signal interface. DI-, DI + for the fire signal input interface, DO-, DO + feedback output interface for the fire. Both interfaces are active signal, need external access to power, DI-, DI + only allows the DC voltage input range is DC5V-30V; DO-, DO + also allows only a DC voltage input range is DC5V-30V, with driving DC12V, DC24V relays and other equipment, both of which do not access to 220V AC signal, in order to avoid damage to the equipment. When the system default input signal fire, triggering all circuits open, feedback output interface connected; when the fire signal is restored, restore the original state of the circuit, the feedback output interface is disconnected; above signals can be programmed to trigger a scene changes. Fifth, installation and connection 1. Installation conditions to be ventilated installation location, pay attention to moisture, shock and dust. 2. Wiring specifications l This module relay switch the output cable: 2.5mm2 copper wire l 485 bus cable: the super five-wire or 4-wire twisted pair 3. Typical systems are typically connected to the system is connected to the module (for reference) as shown below. Enables devices to connect switch control, lighting control (including scene control, etc.) via the control panel 485, system management servers, systems management, and connection with other control systems and so on. Six, functions and operating instructions a relay switch manual control of the module in addition to receiving an external signal switching control, can also be manually controlled switch. 1-4 by operating the manual switch relay circuit, which can control 1 to 4 loops on and off. 2, the machine ID number on the device must be "SILO System Control Software" settings, set to see the software instructions. 3, Scene up to 128 scenes, each scene is a combination of any of the loop together. Scene must pass "SILO system control software" to set, see the software settings. 4, open-loop and open-loop protection delay delay: Each loop can be set to turn on delay, loop-start after that, reaching the loop only when the value of the output of the delay. Effect on delay, while simultaneously launch multiple loops, loop start followed by the delay value to avoid the impact of high current all started. Note: on delay values ??ranging from 0.0 to 25.0 seconds. Circuit protection delay: Each loop can be set up to protect the delay, that is, when a circuit output turns off, in order to protect the load, only time delay to protect the value of the loop output can no longer be controlled. Note: protection delay values ??ranging from 00 to 60 points. On delay value, protect the delay value must be set by "SILO system control software", set reflected instructions. 5. The field is set to run after reboot (power-recovery scenarios set) as the system set to open the field, after restarting the machine will run the last scene when turned off. After the system is set for the specified field, the machine reboots, will run the specified scene. Sets by "SILO system control software", set reflected instructions. The default scenario is not running after the restart. Safe use and maintenance of the bus can not be less than 1.485 16V, otherwise the relay does not work. 2. Each loop must access AC220V ~ 240V power supply through the appropriate circuit breaker. 3. In order to secure the use of relays, should note the following: l For connecting a resistive load, the load current of each loop can be up to 16A. |
Admin>>>
You are the 10258 visitor
Copyright © GuangDong ICP No. 10089450, Wenzhou Sheng Tai Electric Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 10258 visitor
Copyright © GuangDong ICP No. 10089450, Wenzhou Sheng Tai Electric Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility